KR Hellas
본문 바로가기

LOGO

Main Menu

메뉴열기

...

CPR

EN 1090 Certification

Certification of the manufacturing process of structural steel in accordance with EN 1090 during the execution of the CPR certification

EN 1090 Series
  • EN 1090 : Execution of steel structures and aluminium structures
  • EN 1090-1: Requirements for conformity assessment for structural components
  • EN 1090-2: Technical requirements for the execution of steel structures
  • EN 1090-3: Technical requirements for the execution of aluminium structures
  • EN 1090-1: Determination and declaration of the characteristics of a structure
  • EN 1090-2&3 : Verification of manufacturing processes for structural steel manufacturer
EN 1090 - Determination of Execution Classes

EN 1090-2 regulates to select (declare) an execution class of a product and comply with the relevant requirements

※ EXC: Determined according to Risk Assessment (COF) and Complexity (by Owner or designer)

Execution Classes are determined considering the consequence class and category as below

  • Consequence Class (CC)
  • Service Category (SC)
  • Production Category (PC)
Examples of Execution Class
EXC1
  • Supporting structures with steel up to strength class S275
  • Buildings with up to 2 floors (4 floors if detached)
  • Bending beams up to 5m, projection beams up to 2m
  • Stairs & railings in residential buildings
  • Agricultural buildings, e.g. barns
EXC2
  • Supporting structures with steel up to strength class S700
  • Buildings with 2-15 floors
EXC3
  • Supporting structures with steel up to strength class S700
  • Assemblies/stadiums with large surface roof structures
  • Buildings with more than 15 floors
  • edestrian, bicycle, road and railway bridges
  • Crane track
EXC4
  • Bridges (road & rail) over densely populated areas or industrial plants with high hazard potential
  • Safety tanks in nuclear power plants.